Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Sci Rep ; 14(1): 8364, 2024 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600312

RESUMO

This study retrospectively assessed radiographic outcomes and risk factors associated with non-union in femoral shaft fragmentary segmental fractures (AO/OTA 32C3) treated with reamed antegrade intra-medullary nailing. Radiological outcomes, including union and alignment, were evaluated. The risk factors for non-union were investigated, including demographics and treatment-related characteristics, such as the number of interlocking screws, segmentation length, main third fragment length, distance of the main third fragment, width ratio and exposed nail length in one cortex from immediate post-operative radiographs. Multivariate logistic regression was used for statistical analysis. Among 2295 femoral shaft fracture patients from three level-1 trauma centers, 51 met the inclusion criteria. The radiological union was achieved in 37 patients (73%) with a mean union time of 10.7 ± 4.8 months. The acceptable axial alignment was observed in 30 patients (59%). Multiple logistic regression analysis identified only exposed nail length as a significant risk factor for non-union (odds ratio: 1.599, p = 0.003) and the cut-off value was 19.1 mm (sensitivity, 0.786; specificity, 0.811). The study revealed high rates of non-union (27%) and malalignment (41%). Therefore, patients who underwent intramedullary nailing with an exposed nail length greater than 19.1 mm or about twice the nail diameter should be cautioned of the potential non-union.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/efeitos adversos , Estudos Retrospectivos , Pinos Ortopédicos/efeitos adversos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/etiologia , Radiografia , Resultado do Tratamento , Consolidação da Fratura
2.
Clin Orthop Surg ; 15(6): 880-887, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38045574

RESUMO

Background: Vitamin D concentrations are associated with sepsis, pneumonia, and mortality in critically ill patients. However, the role of vitamin D in critically injured patients with trauma remains unknown. This study investigated the effects of vitamin D concentrations on outcomes in critically injured patients with trauma. Methods: A prospective observational study was conducted by randomly selecting 100 patients among those who visited our trauma center. The serum vitamin D concentration was measured upon arrival at the hospital, and the length of stay in a trauma intensive care unit after admission, duration of mechanical ventilation, number of days spent in the hospital, development of complications, and death were investigated. The association between the surveyed variables and vitamin D concentrations was investigated using regression analysis. Results: Of the 100 patients, 69 were men and 31 were women with an average age of 51.7 years. The average intensive care unit stay length was 18.4 days, and 6 patients (5.9%) died. Univariate regression analysis showed that the factors affecting patient mortality were age (p = 0.02), volume of blood transfused within 24 hours of arrival (p = 0.009), systolic blood pressure measured upon hospital arrival (p = 0.01), and serum lactate concentration measured upon hospital arrival (p = 0.03). Multivariate regression analysis showed that the factors affecting patient mortality were age (p = 0.01), volume of blood transfusion (p = 0.04), and systolic blood pressure measured upon hospital arrival (p = 0.01). Conclusions: There were no statistically significant effects of serum vitamin D concentrations in critically ill patients with trauma on death during hospitalization.


Assuntos
Deficiência de Vitamina D , Vitamina D , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Estado Terminal , Centros de Traumatologia , Deficiência de Vitamina D/complicações , Vitaminas , Prognóstico , Tempo de Internação
3.
Sci Rep ; 13(1): 13430, 2023 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-37596315

RESUMO

Despite the variety of treatment methods, comminuted inferior pole fractures of the patella remain difficult and technically demanding to achieve stable internal fixation. The purpose of this study is to evaluate the clinical outcomes of rim plate-augmented separate vertical wiring with supplementary fixation in the management of comminuted inferior pole fractures, AO/OTA 34-A1, C2, and C3, which has the secondary horizontal fracture line on lower articular boundary. From our study, bony union was achieved in all patients at an average of 3.1 ± 1.4 months after surgery. There was no patient with loss of reduction, fixation failure, or infection during follow-up. The average final range of motion was 131.6° ± 7.2°. Lysholm knee scores gradually increased over 3, 6, 9, and 12 months postoperatively by 58.7, 74.0, 82.9, and 89.4, respectively. Isokinetic peak torque deficit of the knee extensor muscles in 3, 6, 9, and 12 months postoperatively was 59.9%, 49.7%, 35.7%, and 28.1%, respectively. The rim plate-augmented separate vertical wiring with supplementary fixation for the treatment of patellar fracture associated comminuted inferior pole is effective and can be safely applied AO/OTA 34-C2 or C3 with favorable outcomes.


Assuntos
Fraturas Ósseas , Traumatismos do Joelho , Procedimentos de Cirurgia Plástica , Humanos , Fraturas Ósseas/cirurgia , Terapia por Exercício , Fixação Interna de Fraturas
4.
Injury ; 52(6): 1403-1409, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33827775

RESUMO

INTRODUCTION: The aim of this study was to analyze and describe the fracture patterns of the acetabular posterior wall based on quantitative measurements of the fracture characteristics. MATERIALS AND METHODS: Computed tomography images of 51 patients with acetabular posterior wall fractures from an initial cohort of 216 acetabular fractures were imported into a three-dimensional (3D) virtual software. The reconstructed 3D images were utilized to evaluate the following: (i) fracture line mapping on the inner articular and retro-acetabular surfaces, (ii) common zones of fracture and marginal impaction, and (iii) categorization by location and pattern of comminution. The clock-face position was applied for description: the midpoint of the transverse acetabular ligament served as the +180° reference point, and the 0° reference point was set perpendicular to the ligament. The fracture angle on the articular surface was defined as the intersection between the start and end points. The fracture span on the retro-acetabular surface was defined as the ratio of the perpendicular distance, which is between the fracture beak and acetabular rim, to the entire length, which is from the edge to the rim. Quantitative measurements were performed, and the fracture patterns were analyzed. A color scale bar was used to visualize the common and marginal impaction zones. RESULTS: The articular surface mapping of all the cases demonstrated that the average starting point of the fracture line was +6.2° (±12.8°) and the endpoint was 96.7° (±13.3°), and the average fracture angle was 119.6° (±7.6°) with 80.6% of the fragments having angles within 18.7-117°. The retro-acetabular surface mapping demonstrated that the average fracture span was 0.65 ±0.20, and 61.7 % of the fracture lines were located within 0.6 to 0.9. Marginal impaction was found in 21 cases (21/51, 41.2%; range: between +7° and +105°). CONCLUSION: The fracture maps showed fracture patterns and recurrent fracture zones on the articular and retro-acetabular surfaces. However, there was no remarkable pattern of marginal impaction. LEVEL OF EVIDENCE: Retrospective cohort study.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Articulação do Quadril , Humanos , Estudos Retrospectivos , Software
5.
Asian J Surg ; 44(1): 66-71, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33262045

RESUMO

The incidence of intertrochanteric femoral fractures has rapidly increased with the extended lifespan of the elderly population. Surgery enables early ambulation by achieving anatomic reduction and stable internal fixation. However, reduction usually involves postoperative evaluation. Here, we present reliable parameters obtained from analyses of three-dimensional computed tomography images from cadavers to serve as guidelines during the reduction of intertrochanteric fractures. We included 184 three-dimensional modeling samples from cadavers placed in two standardized positions, similar to C-arm imaging. We recorded the level of the orthogonal line from the greater trochanter (GT) tip to the femoral head (GT orthogonal line [GTOL]) in the anteroposterior view and the line along the anterior femoral cortex passing through the femoral head (anterior cortical line) in the axial view. Correlations between these lines and angular alignments were statistically determined. The GTOL passed above the femoral head center at mean 2.36 mm in all patients; 77.17% of such instances were in the upper second quadrant of the femoral head. The anterior cortical line passed under the femoral head center at mean 10.82 mm; 73.37% of such instances were in the inferior one-third of the femoral head. Consistent correlations were found between the GTOL and neck-shaft angle and between the anterior cortical line and anteversion. The GTOL and anterior cortical line passed through a constant level of the femoral head in most samples and were correlated with angular alignments. The intraoperative use of these simple imaginary lines improves the intertrochanteric fracture reduction quality.


Assuntos
Cabeça do Fêmur/diagnóstico por imagem , Fixação Interna de Fraturas/métodos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Monitorização Intraoperatória/métodos , Adulto , Anteversão Óssea/diagnóstico por imagem , Cadáver , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Adulto Jovem
6.
J Bone Joint Surg Am ; 102(14): 1269-1278, 2020 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-32675677

RESUMO

BACKGROUND: Little is known about the volumetric changes of grafted bone over time when using the induced membrane technique. This study investigates the volumetric changes of bone graft using serial computed tomographic (CT) scans following the induced membrane technique. METHODS: Patients with critical-sized bone defects had serial CT scans after undergoing bone-grafting using the induced membrane technique. CT scans to evaluate the volume of bone graft were obtained immediately postoperatively and at 6 and 12 months. The change in the volume of bone graft was determined at 6 and 12 months postoperatively. Patient demographic characteristics, the location and composition of the bone graft, and the type of fixation construct were analyzed. RESULTS: Forty patients met inclusion criteria. There were 27 tibiae and 13 femora with a mean size defect of 8.6 cm (range, 2.5 to 20.6 cm). Of these patients, 21 received autograft with cancellous bone graft and 19 received mixed autogenous bone with demineralized bone matrix (DBM) at a mean time of 17 weeks after the membrane formation. For the first 6 months, there was an overall osseous resorption of -9.9%. The overall graft volume from 6 to 12 months demonstrated an increase of osseous volume by +1.6%. For the entire 12-month period, there was a mean graft volume resorption of -8.3%. A correlation was found between the early volumetric changes of grafted bone and the percentage of DBM in the graft mixture. A correlation was also found between the late volumetric changes and the location of defect or the type of fixation. CONCLUSIONS: At 1 year after use of the induced membrane technique for the treatment of a critical-sized bone defect, resorption of the grafted bone averaged -8.3%. The volumetric changes were influenced by the property of the grafted bone, the fixation construct, and the location of the defect. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Reabsorção Óssea/diagnóstico por imagem , Transplante Ósseo/métodos , Fíbula/cirurgia , Tíbia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Feminino , Fíbula/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto Jovem
7.
J Shoulder Elbow Surg ; 29(8): 1554-1563, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32713465

RESUMO

BACKGROUND: We investigated the overall clinical outcome of the expanded paratricipital approach in complex articular fractures of the distal humerus and the effect of lack of visualization in the surgical field. In addition, we performed a cadaveric study to investigate the expansion or limitation of articular access in the expanded paratricipital approach. METHODS: Forty-one AO/OTA type 13C fracture cases treated using the expanded paratricipital approach at a single trauma center from 2013 to 2017 were enrolled in this study. We evaluated the overall clinical outcome and analyzed the effect of lack of visualization in the surgical field with the expanded paratricipital approach by comparing outcomes between 2 groups classified by the location of the main articular fracture (group 1, limited visualization; group 2, without limited visualization). The length of inaccessible and accessible articular segments were analyzed using 40 matched-pair elbows. RESULTS: The average duration of follow-up was 15.1 months. All fractures (type C1 in 11 cases, type C2 in 21, and type C3 in 9) were radiologically healed at 3.2 months after surgery. No cases required additional surgery because of implant irritation. The average Mayo Elbow Performance Score was 90.5. The mean Disabilities of the Arm, Shoulder and Hand score was 18.5. Among the 41 cases, the limited visualization group (group 1, n = 21) had a longer surgical time and higher percentage of nonanatomic reduction than group 2. Although the expanded paratricipital approach allowed more articular exposure than the conventional approach, there was still a 20mm inaccessible articular segment (30% of transepicondylar width) in cadaveric dissection. CONCLUSIONS: The expanded paratricipital approach can be used in type C1, type C2, and selective type C3 articular fractures of the distal humerus with favorable results. Relative to surgical times and achieving anatomic reduction, it is more successful in a fracture with a main articular fragment and with good visualization.


Assuntos
Articulação do Cotovelo/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Fraturas Intra-Articulares/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Articulação do Cotovelo/diagnóstico por imagem , Feminino , Humanos , Fraturas do Úmero/diagnóstico , Úmero/diagnóstico por imagem , Fraturas Intra-Articulares/diagnóstico , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Radiologia , Resultado do Tratamento , Adulto Jovem , Lesões no Cotovelo
8.
Arch Orthop Trauma Surg ; 139(11): 1587-1597, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31286182

RESUMO

PURPOSE: The purposes of the study were to introduce surgical technique of fragment-specific fixation technique using multiple 2.7-mm variable-angle locking compression plates (VA LCPs) in comminuted posterior wall acetabular fractures and reported its clinical results. PATIENTS AND METHODS: Among the 68 patients, 23 with comminuted posterior wall factures with ≥ 3 fragments in the CT scan and no column involvement with a minimum follow-up duration of 12 months were enrolled in this study. We evaluated the clinical results after the treatment of comminuted posterior wall acetabular fractures via the fragment-specific fixation technique using 2.7-mm variable-angle locking compression plates (VA LCPs) retrospectively. RESULTS: The average duration of follow-up was 26.8 months. Anatomical reduction was achieved in eighteen patients. Imperfect reduction was achieved in five patients. 22 patients achieved fracture union and one patient underwent revision surgery owing to acute postoperative infection. There were no complications, including loss of reduction, fixative failures, sciatic nerve palsy, heterotopic ossification, and early posttraumatic arthritis among 22 patients. The average functional outcome was measured as 'very good'. CONCLUSION: Fragment-specific fixation technique using 2.7-mm VA LCPs for comminuted posterior wall acetabular fractures could be an acceptable alternative means of surgical fixation.


Assuntos
Acetábulo/cirurgia , Fixação Interna de Fraturas , Fraturas Cominutivas/cirurgia , Placas Ósseas , Humanos , Estudos Retrospectivos , Resultado do Tratamento
9.
J Orthop Trauma ; 33(4): e143-e150, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30893222

RESUMO

The aim of this study was to introduce various applications of miniplate augmented tension-band wiring (TBW) for comminuted patella fractures and to evaluate the clinical outcomes. Comminuted articular patella fractures were managed with anterior cortical miniplate fixation with a TBW technique from January 2014 to January 2016. The primary end point was radiographic union. Secondary end points were complications related to the procedure. Functional outcomes including range of motion were also evaluated. Thirty patients were followed up for a mean of 20 months (range, 12-28) postoperatively. The primary union rate was 96% (29 of 30 patients). Mean time to union was 3.2 months. One patient required additional surgery because of acute postoperative infection. Twenty-five patients recovered a full range of motion relative to the contralateral limb. The mean Bostman score at the last follow-up was 28.6 points (range, 26-30). In conclusion, miniplate augmented TBW is a versatile and useful technique for comminuted patella fracture fixation.


Assuntos
Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas/instrumentação , Fraturas Cominutivas/cirurgia , Patela/lesões , Feminino , Fraturas Cominutivas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Patela/diagnóstico por imagem , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
10.
Ann Surg Treat Res ; 96(1): 14-18, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30603629

RESUMO

PURPOSE: Laparoscopic major liver resection (major LLR) remains a challenging procedure because of the technical difficulty. Several significant technical innovations have been applied in our center since 2012. They include routine application of bipolar electrocautery, initiation of temporary increase of intra-abdominal pressure during bleeding events from veins to balance the central venous pressure, and use of temporary inflow control of the Glissonean pedicle. This study evaluated the impact of these technique modifications in patients with major LLR. METHODS: Between January 2004 and February 2015, a total of 606 patients underwent LLR at Samsung Medical Center in Seoul, Korea. Major LLR was employed in 233 cases. All major LLR procedures were anatomical resections performed with a totally laparoscopic approach. We compared surgical parameters of right hepatectomy (RH), left hepatectomy (LH), and right posterior sectionectomy (RPS) before and after 2012. RESULTS: Open conversion rates of RH and LH and estimated blood loss in RPS significantly decreased after 2012. The postoperative complication rate of major LLR was 12.7% and was similar before and after 2012. Bile leakage was the most common complication (3.2%). CONCLUSION: The modifications of surgical techniques resulted in good outcomes for laparoscopic major LLR. We recommend routine application of these techniques to improve outcomes, especially in patients requiring major liver resection.

11.
Injury ; 49(10): 1912-1921, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30060889

RESUMO

INTRODUCTION: Local delivery of high dose antibiotics in the form of antibiotic impregnated polymethyl methacrylate (PMMA) cement beads or coated rods is commonly used in the management of long bone infections. The downsides of antibiotic cement beads for intramedullary long bone infections are associated with difficulty in removal from the medullary canal, bead breakage, and lack of stability. Antibiotic cement-coated smooth flexible guide wires, rods and nails can have complications such as delamination or debonding of the cement. In addition, the current techniques for cement rod insertion have a risk of iatrogenic joint contamination. To improve upon this technique and decrease potential complications, we propose the use of an antibiotic cement-coated hinged threaded rod as a temporary intramedullary spacer. This technique utilizes both an antegrade and retrograde insertion of the threaded rod into the medullary canal through the bony defect site with connection at the hinge to treat intramedullary long bone infections and infected nonunions. MATERIAL AND METHODS: A total of 40 patients were included in the study. The details in making the cement rod were well documented. The shape of cement rod and the integrity of the cement at the time of rod insertion and rod removal were compared to identify any cement debonding or delamination. Potential postoperative complications including iatrogenic joint infection, displacement or breakage of the threaded cement rods, and fracture displacement were all carefully documented. The preliminary biological effect of the initial debridement and antibiotic cement rod placement was determined using the negative conversion rate of intraoperative cultures. RESULTS: A single antibiotic coated threaded rod was inserted in 18 cases. Two separate antibiotic coated threaded rods were inserted and connected via hinge in 22 cases. There were zero cases of rod breakage and no secondary loss of reduction from antibiotic rod placement to the definitive staged operation. There were zero iatrogenic joint infections. There were zero cases of cement debonding or delamination from the rod. The conversion rate to a negative culture after initial debridement and antibiotic rod placement was 85% (34/40 cases). CONCLUSIONS: The use of an antibiotic coated cement threaded rod with a hinge as an intramedullary spacer provides the benefits of local antibiotic delivery, offers improved construct stability, makes implant removal easier without delamination of the cement mantle, and utilizes the versatility of a hinge to prevent violation of native joints when treating infected nonunions and intramedullary long bone infections.


Assuntos
Antibacterianos/administração & dosagem , Sistemas de Liberação de Medicamentos/instrumentação , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas não Consolidadas/cirurgia , Osteomielite/tratamento farmacológico , Complicações Pós-Operatórias/microbiologia , Fraturas da Tíbia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos/farmacologia , Pinos Ortopédicos , Desbridamento , Feminino , Fraturas do Fêmur/microbiologia , Consolidação da Fratura/fisiologia , Fraturas não Consolidadas/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteomielite/prevenção & controle , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Fraturas da Tíbia/microbiologia , Resultado do Tratamento
12.
J Orthop Trauma ; 32(5): e157-e160, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29356799

RESUMO

OBJECTIVE: To evaluate the effectiveness of an additional rim plate [3.5-mm precontoured locking compression plate (LCP)] for stabilizing the posterolateral fragment in lateral tibial plateau fractures. METHODS: Standard lateral locking plates [either a proximal tibial plate (PTP) or a proximal tibial locking plate (PTLP)] were applied to 40 matched pair knees from 20 fresh-frozen cadavers followed by the application of a secondary rim plate [variable angle LCP (VALCP)] posterior laterally. RESULTS: The mean ratio of supported articular surface in the PTP group was 0.692, whereas that in the PTLP group was 0.569. This difference was statistically significant (P < 0.001). Additional rim plating with a VALCP could only be performed for 27 of 40 knees; 8 of 20 knees in the PTP group and 5 of 20 knees in the PTLP group could not be fitted with a VALCP due to anatomic limitations. For the total standard plating group alone, the mean ratio of supported articular surface was 0.596, whereas the mean ratio of supported articular surface with additional rim plating was 0.798 (P < 0.001). In contrast, additional rim plating was possible for more knees that received a PTLP than a PTP. Ultimately, there was no significant difference in the ratio of supported articular surface after additional rim plating between the 2 different types of standard plates (P = 0.087). CONCLUSION: Our results identified a bare area in the posterolateral corner of the lateral plateau that was unsupported by rafting screws following conventional, 3.5-mm, precontoured LCP plating. Thus, additional rim plating may be useful for treating plateau fractures with a posterolateral fragment.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia , Cadáver , Fixação Interna de Fraturas/métodos , Humanos , Tíbia/lesões
13.
Arch Orthop Trauma Surg ; 138(2): 195-202, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29058078

RESUMO

INTRODUCTION: We present the surgical technique of rim-plate-augmented separate vertical wiring for comminuted inferior pole fracture of the patella and report the clinical outcomes. MATERIALS AND METHODS: Between July 2013 and January 2016, 13 patients (7 male and 6 female) who were diagnosed with comminuted inferior pole fracture of the patella in preoperative computed tomography and underwent a minimum of 1 year of follow-up were enrolled in this study. Mean patient age was 57.7 years (range 28-72 years). All patients underwent open reduction and internal fixation by rim-plate-augmented separate vertical wiring. Bony union, complications, range of motion and Bostman score were the clinical outcomes. RESULTS: Bony union was achieved in all cases at an average of 10 weeks after surgery (range 8-12). There was no loss of reduction and fixative failure during follow-up. The average range of motion was 127° (range 120°-130°). The mean Bostman score at last follow-up was 29.6 points (range 27-30) and graded excellent in 12 patients. CONCLUSION: Rim-plate-augmented separate vertical wiring demonstrated secure fixation and favorable clinical outcomes. This study provides evidence for its effectiveness as a fixation method for treating displaced, comminuted inferior pole fracture of the patella.


Assuntos
Fios Ortopédicos , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Patela/lesões , Patela/cirurgia , Adulto , Idoso , Feminino , Fraturas Cominutivas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Patela/diagnóstico por imagem
14.
Injury ; 48(10): 2292-2305, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28802745

RESUMO

OBJECTIVES: The objectives of the study were to introduce a circumferential bone graft around an absorbable gelatin sponge core using an induced membrane technique, to assess its ability to reduce the required amount of graft and to maintain the bone graft, and to evaluate the clinical outcomes in the management of critical-size bone defects. PATIENTS AND METHODS: Circumferential bone grafting using a staged induced membrane technique for managing critical-size bone defects was performed in 21 patients. Postoperative computed tomography scans were performed 7days after Hemovac drain removal and 3 months after bone grafting. Volumetric measurements of the defect size, gelatin sponge proportion, and amount of grafted bone were performed by two independent observers using three-dimensional (3D) software. RESULTS: The critical-size defects were located at the metadiaphyseal area of 11 tibias, eight femurs, and two humeri. The average defect size was 8.9cm in length and 65.2cm3 in volume. The absorbable gelatin sponge core replaced 21.4% (average) of the defect volume. There was no significant deterioration in the shape of the grafted bone among the serial 3D models. Eighteen patients (86%) were healed radiographically at 9.1 months (average). CONCLUSION: Our study suggests that circumferential bone grafting in association with the induced membrane technique could reduce the required amount of bone graft and adequately maintain graft position and shape, with favourable clinical outcomes.


Assuntos
Transplante Ósseo , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Consolidação da Fratura/fisiologia , Fraturas do Úmero/cirurgia , Osteogênese/fisiologia , Fraturas da Tíbia/cirurgia , Adulto , Idoso , Transplante Ósseo/métodos , Terapia Combinada , Desbridamento/métodos , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/fisiopatologia , Esponja de Gelatina Absorvível , Sobrevivência de Enxerto , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/fisiopatologia , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
15.
Int Orthop ; 41(9): 1887-1897, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28735430

RESUMO

PURPOSE: To review available approaches and fixation methods for posterolateral fracture fragment (PLF) in tibial plateau fracture, and to propose an algorithm to treat various types of plateau fractures which all involve the PLF. METHODS: This article reviews multiple surgical approaches for PLF and suggests an algorithm for suitable approach and fixation method according to PLF with combined plateau fracture. RESULTS: The modified anterolateral approach is a suitable single approach for fractures with a PLF combined with an anterolateral plateau fracture and for isolated posterolateral fracture fragments. For a multicolumn tibia plateau fracture involving the lateral, medial and posterior columns, dual approaches (modified anterolateral and posteromedial approach) can be used to access the entire plateau area. CONCLUSIONS: When considering approaches of this complex fracture pattern, one must consider local soft tissue condition, plateau fracture morphology, associated injuries, and fixation options. After review of multiple approaches described in the literature for PLF fixation, we can suggest an algorithm for the approach and fixation to treat tibial plateau fractures with posterolateral fracture fragments.


Assuntos
Placas Ósseas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fraturas Intra-Articulares/cirurgia , Fraturas da Tíbia/cirurgia , Adulto , Algoritmos , Feminino , Humanos , Traumatismos do Joelho/cirurgia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Tíbia/cirurgia
16.
J Laparoendosc Adv Surg Tech A ; 27(8): 799-803, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28080205

RESUMO

INTRODUCTION: Although laparoscopic liver resection (LLR) has developed rapidly, its usefulness for the treatment of large tumors is less clear, due to concerns about compromising oncological principles and patient safety. The purpose of this study was to explore the feasibility and safety of LLR for the treatment of hepatocellular carcinoma (HCC) with a tumor size larger than 5 cm. PATIENTS AND METHODS: From January 2007 to December 2014, we performed LLR in 45 patients with HCC with a tumor size ≥5 cm. Perioperative outcome, tumor recurrence, and overall patient survival were analyzed. RESULTS: Median age was 60 years (interquartile range [IQR] 52-68) and 64.4% (29/45) were male. Seven patients (15.6%) had larger than 10 cm of HCC. No operative deaths occurred and six of the laparoscopic procedures were converted to open resection (conversion rate 13.3%). Median operation time was 365 minutes (IQR 277-443) and median estimated blood loss (EBL) was 400.0 mL (IQR 275-600). There was no R1 or R2 resection and median resection margin was 19.0 mm (IQR 8.0-33.0). Complications above Clavien-Dindo classification grade III occurred in four patients (8.9%). The median overall follow-up time was 10.7 month (range 1.1-62.1). One-year recurrence free survival (RFS) and overall survival (OS) were 86.0% and 95.5%, and 3-year RFS and OS were 70.7% and 86.0%. CONCLUSION: LLR appears safe and feasible in patients with HCC with a tumor size larger than 5 cm. Expansion of indication for LLR in patients with HCC may be considered.


Assuntos
Carcinoma Hepatocelular/cirurgia , Hepatectomia/métodos , Laparoscopia/métodos , Neoplasias Hepáticas/cirurgia , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Estudos de Viabilidade , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/cirurgia , Duração da Cirurgia , Análise de Sobrevida , Carga Tumoral
18.
Arch Orthop Trauma Surg ; 136(7): 945-55, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27245452

RESUMO

A3 intertrochanteric fracture has a higher incidence of intraoperative re-displacement than A1 and 2. The authors have also experienced difficulty with maintenance of reduction in A3 intertrochanteric fractures, as the technique depends on manual effort and can fail easily during the procedure. It induced us to develop this surgical technique to ease the surgical procedure and improve clinical outcomes. This paper introduces a modified provisional guide pin fixation technique applicable to even AO/OTA A3 intertrochanteric fractures, and presents preliminary results of 11 patients who were treated by provisional pin fixation-assisted nailing in A3 intertrochanteric fractures. Using this technique, we have reduced the chances of intraoperative reduction loss and achieved favorable clinical outcomes.


Assuntos
Pinos Ortopédicos/efeitos adversos , Fixação Intramedular de Fraturas/métodos , Fraturas do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Fixação Intramedular de Fraturas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias
19.
Transpl Int ; 29(8): 890-6, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27112373

RESUMO

Partial liver grafts used in living donor liver transplantation (LDLT) may have multiple hepatic artery (HA) stumps. This study was designed to validate the safety of partial reconstruction of multiple HAs in pediatric LDLT cases. From January 2000 to June 2014, 136 pediatric LDLT recipients were categorized into three groups: single HA group (Group 1, n = 74), multiple HAs with total reconstruction group (Group 2, n = 23), and multiple HAs with partial reconstruction group (Group 3, n = 39). Partial reconstruction was performed only when there was pulsatile back-bleeding after larger HA reconstruction and sufficient intrahepatic arterial flow was confirmed by Doppler ultrasound (DUS). There was no significant difference in biliary complication rate, artery complication rate, patient survival, and graft survival among these groups. Risk factor analysis revealed that the presence of multiple HAs and partial reconstruction of multiple HAs were not risk factors of biliary anastomosis stricture. In conclusion, partial reconstruction of HAs during pediatric LDLT using a left liver graft with multiple HA stumps does not increase the risk of biliary anastomosis stricture or affect graft survival when intrahepatic arterial communication is confirmed by pulsatile back-bleeding and DUS.


Assuntos
Ductos Biliares/cirurgia , Artéria Hepática/cirurgia , Transplante de Fígado/métodos , Fígado/cirurgia , Doadores Vivos , Procedimentos de Cirurgia Plástica , Sistema ABO de Grupos Sanguíneos , Anastomose Cirúrgica , Criança , Pré-Escolar , Feminino , Sobrevivência de Enxerto , Humanos , Lactente , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Transplantes , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares
20.
Arch Orthop Trauma Surg ; 136(1): 55-63, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26681185

RESUMO

INTRODUCTION: During nailing of intertrochanteric fractures, there is always a risk of reduction loss despite achieving an acceptable reduction status after a percutaneous procedure. Most surgeons usually attempted to maintain the reduction with a manual endeavor. However, we experienced varying amounts of intraoperative reduction loss and had to perform readjustments several times. These struggles motivated us to attempt provisional pin fixation as an alternative method. The purpose of this study was to analyze the factors affecting intraoperative reduction loss, especially in comparison between two methods. MATERIALS AND METHODS: Sixty-eight patients with intertrochanteric fractures were included. They were divided into two groups based on the method, by retrospective analysis of the intraoperative c-arm image. In the manual maintenance group, an assistant maintained the instruments during the procedure. In the provisional pin fixation group, the reduction was temporaryily held by a 3.2mm guide pin fixation across the fracture. A displacement of more than one cortical thickness in any plane or angular deformity during any point in the procedure after acceptable reduction was judged as an intraoperative reduction loss. Multivariate logistic regression was used for statistical analysis. RESULTS: The number of cases with intraoperative reduction loss was 18 (18 of 38, 46.1%) in the manual maintenance group and 6 (6 of 30, 20.0%) in the provisional pin fixation group. The odds ratio of intraoperative reduction loss in the manual maintenance group was 5.182 (95% confidence interval, 1.455-18.452) compared with the provisional pin fixation group as the reference. CONCLUSIONS: As a reasonable approach for maintaining reduction, provisional pin fixation can significantly decrease intraoperative reduction loss after percutaneous reduction of intertrochanteric fractures during nailing.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas/métodos , Fraturas do Quadril/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fixação Intramedular de Fraturas/instrumentação , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...